BCR8PM-14LJ Triac DATASHEET

DATASHEET SEARCH FORM

BCR8PM-14LJ ELECTRICAL SPECIFICATIONS

PARAMETER SYMBOL VALUES UNITS
Type Triac
Maximum repetitive peak and off-state voltage VDRM 700 V
Maximum RMS on-state current IT(RMS) 8 A
Non repetitive surge peak on-state current ITSM 80 A
Maximum operating junction and storage temperature range Tstg, Tj ..150 °C
Junction to case thermal resistance RTH(j-c) 4.3 K/W
Triggering gate voltage VGT 1.5 V
Peak on-state voltage drop VTM 1.6 V
Triggering gate current IGT 0.03 mA
Package TO-220F

BCR8PM-14LJ Replacements

SYMBOL VALUES UNITS
Type
PGM > W
VDRM > V
IT(AVR) > A
IT(RMS) > A
ITSM > A
dI/dt > A/µs
dV/dt > V/µs
Tstg, Tj > °C
RTH(j-a) < K/W
RTH(j-c) < K/W
VGT < V
VTM < V
IGT < mA
IH < mA
Package

Replacement Search

BCR8PM-14LJ Datasheet. Page #1

BCR8PM-14LJ
 datasheet

Page #2

BCR8PM-14LJ
 datasheet #2

Description

 Preliminary Datasheet BCR8PM-14LJ R07DS0515EJ0100 Triac Rev.1.00 Medium Power Use Oct 14, 2011 Features  IT (RMS) : 8 A  The Product guaranteed maximum junction temperature 150C  VDRM : 800 V(Tj=125 )  Insulated Type  IFGTI, IRGTI, IRGT III : 30 mA  Planar Type  Viso: 2000 V  UL Recognized: File No. E223904 Outline RENESAS Package code: PRSS0003AA-A (Package name: TO-220F) 2 1. T1 Terminal 2. T2 Terminal 3. Gate Terminal 3 1