FT2514MW Triac DATASHEET

DATASHEET SEARCH FORM

FT2514MW ELECTRICAL SPECIFICATIONS

PARAMETER SYMBOL VALUES UNITS
Type Triac
Maximum repetitive peak and off-state voltage VDRM 600 V
Maximum RMS on-state current IT(RMS) 25 A
Non repetitive surge peak on-state current ITSM 200 A
Critical rate of rise of off-state voltage dV/dt 500 V/µs
Triggering gate current IGT 35 mA
Package TO-220F

FT2514MW Replacements

SYMBOL VALUES UNITS
Type
PGM > W
VDRM > V
IT(AVR) > A
IT(RMS) > A
ITSM > A
dI/dt > A/µs
dV/dt > V/µs
Tstg, Tj > °C
RTH(j-a) < K/W
RTH(j-c) < K/W
VGT < V
VTM < V
IGT < mA
IH < mA
Package

Replacement Search

FT2514MW Datasheet. Page #1

FT2514MW
 datasheet

Page #2

FT2514MW
 datasheet #2

Description

FT25...W HIGH COMMUTATION TRIAC TO220-F Gate Trigger Current On-State Current (FULLY ISOLATED CASE) 25 Amp £ 50 mA Off-State Voltage 200 V ÷ 800 V MT1 MT2 G This series of TRIACs uses a high performance PNPN technology. These parts are intended for general purpose AC switching applications with highly inductive loads. Absolute Maximum Ratings, according to IEC publication No. 134 SYMBOL PARAMETER CONDITIONS Value Unit IT(RMS) RMS On-state Current (full sine wave) All Cond