HTU4-600 ELECTRICAL SPECIFICATIONS

PARAMETER SYMBOL VALUES UNITS
Type Triac
Maximum repetitive peak and off-state voltage VDRM 600 V
Maximum RMS on-state current IT(RMS) 4 A
Triggering gate voltage VGT 1.4 V
Peak on-state voltage drop VTM 1.7 V
Triggering gate current IGT 5 mA
Holding current IH 10 mA
Package TO-251

HTU4-600 Replacements

SYMBOL VALUES UNITS
Type
PGM > W
VDRM > V
IT(AVR) > A
IT(RMS) > A
ITSM > A
dI/dt > A/µs
dV/dt > V/µs
Tstg, Tj > °C
RTH(j-a) < K/W
RTH(j-c) < K/W
VGT < V
VTM < V
IGT < mA
IH < mA
Package

Replacement Search

HTU4-600 Datasheet. Page #1

HTU4-600
 datasheet

Page #2

HTU4-600
 datasheet #2

Description

VDRM = 600 V IT(RMS) = 4.0 A HTD4-600 / HTU4-600 600V 4A TRIAC 1.T1 2. T2 3. Gate FEATURES TO-251 TO-252 2  Repetitive Peak Off-State Voltage: 600V 1  R.M.S On-State Current (IT(RMS) = 4A) 1 3 2  High Commutation dv/dt 3  Sensitive Gate Triggering 4 Mode HTU4-600 HTD4-600 General Description The devices is sensitive gate TRIAC suitable for direct coupling to TTL,HTL,CMOS and application such as various logic functions, low power AC switching applications, such