SC261E ELECTRICAL SPECIFICATIONS

PARAMETER SYMBOL VALUES UNITS
Type Triac
Maximum repetitive peak and off-state voltage VDRM 500 V
Maximum RMS on-state current IT(RMS) 25 A
Non repetitive surge peak on-state current ITSM 250 A
Triggering gate voltage VGT 2.5 V
Peak on-state voltage drop VTM 1.58 V
Triggering gate current IGT 50 mA
Holding current IH 75 mA
Package DIGI-PF1

SC261E Replacements

SYMBOL VALUES UNITS
Type
PGM > W
VDRM > V
IT(AVR) > A
IT(RMS) > A
ITSM > A
dI/dt > A/µs
dV/dt > V/µs
Tstg, Tj > °C
RTH(j-a) < K/W
RTH(j-c) < K/W
VGT < V
VTM < V
IGT < mA
IH < mA
Package

Replacement Search

SC261E Datasheet. Page #1

SC261E
 datasheet

Page #2

SC261E
 datasheet #2

Description

DI GI TRON S EMI CONDUCTORS SC260, SC260()3, SC261(MAC261) SERIES THYRISTORS Available Non-RoHS (standard) or RoHS compliant (add PBF suffix). Available as “HR” (high reliability) screened per MIL-PRF-19500, JANTX level. Add “HR” suffix to base part number. MAXIMUM RATINGS Rating Symbol Value Unit Repetitive Peak Off-Stage Voltage VDRM Volts (TC = -40°C to +115°C) SC260B, SC260B3, SC261B (MAC261B) 200 SC260D, SC260D3, SC261D (MAC261D) 400 SC260E, SC260E3, SC261E (